How to install a cooling fan in a Pegasus Kiosk
PURPOSE
You need to know how to wire a Micrologic cooling fan in a Gen1 Pegasus kiosk.
PROCESS
Mounting
- Mount the cooling fan in the top-back portion of the kiosk as shown in the images below.
Wiring
- Install the jumper wires:
- Negative from 2 to 4
- Connect 5 and 6
- Positive from 1 to 3
- Positive lead connected to 1
- Negative lead connected to 4
- Connect the positive lead from the cooling fan to 23 on the thermostat. Run a positive lead from 24 on the cooling fan.
- Connect the positive lead from 24 on the thermostat to the red 24 V terminal block as shown in the image below.
- Connect the negative lead from the cooler fan to the black 24 V terminal block as shown.
- The cooling fan is now wired for operation.